Victron energy VE.Net DC Datasheet Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 84
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
27
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: sales@victronenergy.com | www.victronenergy.com
EasySolar EasySolar 12/1600/70 EasySolar 24/1600/40
Inverter/charger
Transfer switch 16 A
INVERTER
Input voltage range 9,5 – 17 V 19 – 33 V
“Heavy duty” output AC 0 16 A
Output AC1, 2, 3
Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1% (1)
Cont. output power at 25 °C (3) 1600 VA / 1300 W
Cont. output power at 40 °C 1200 W
Peak power 3000 W
Maximum efficiency 92% 94%
Zero-load power 8 W 10 W
Zero load power in search mode 2 W 3 W
CHARGER
AC Input
Input voltage range: 187-265 VAC
Input frequency: 45 – 65 Hz Power factor: 1
Charge voltage 'absorption' 14,4 / 28,8 V
Charge voltage 'float' 13,8 / 27,6 V
Storage mode 13,2 / 26,4 V
Charge current house battery (4) 70 A 40 A
Charge current starter battery (A) 4
Battery temperature sensor yes
Programmable relay (5) yes
Protection (2) a - g
Solar Charge Controller
Maximum output current 50 A
Maximum PV power, 6a,b) 700 W 1400 W
Maximum PV open circuit voltage 100 V 100 V
Maximum efficiency 98 %
Self-consumption 10 mA
Charge voltage 'absorption', default setting 14,4 V 28,8 V
Charge voltage 'float', default setting 13,8 V 27,6 V
Charge algorithm multi-stage adaptive
Temperature compensation -16 mV / °C resp. -32 mV / °C
Protection a - g
COMMON CHARACTERISTICS
Operating temp. range -20 to +50°C (fan assisted cooling)
Humidity (non condensing): max 95%
ENCLOSURE
Material & Colour aluminium (blue RAL 5012)
Protection category IP 21
Battery-connection Battery cables of 1.5 meter
PV connection Three sets of MC4 (PV-ST01) PV connectors.
230 V AC-connection G-ST18i connector
Weight 15 kg
Dimensions (hxwxd) 745 x 214 x 110 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29, EN 62109
Emission / Immunity EN55014-1, EN 55014-2, EN 61000-3-3
Automotive Directive 2004/104/EC
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non linear load, crest factor 3:1
4) At 25 °C ambient
5) Programmable relay which can be set for general alarm, DC
undervoltage or genset start signal function
6a) If more PV power is connected, the controller will limit input power to
700W resp. 1400W
6b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V
EasySolar 12V and 24V: the all-in-one solar power solution
Page view 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 83 84

Comments to this Manuals

No comments